Pastry Cases

 

 

•    Enough time has passed for products to be cooled. 
•    Ventilation holes are not blocked. 
 

The equipment is working too loud...– Make sure that: 

•    The equipment is standing stably and properly levelled. 
•    Furniture adjoining the equipment does not vibrate when self-contained compressor is working. 
 

A noise made by the operating device is normal. The units are equipped with 
ventilators, engines and compressors, which turn on and off automatically. Each 
compressor makes certain noises when operating. These sounds are made by the 
aggregate engine and by cooling agent flowing through the circuit. This 
phenomenon constitutes a technical feature of cooling devices and does not signify 
equipment failure. 

 

Steam precipitation on glass is normal in event of high relative air humidity 
exceeding 55% and does not require calling for service. 

6.2 Service 

IGLOO Refrigeration service  

Telephone number:

 416-663-3051 or (toll free) 1-888-408-8819   

E-mail:

 [email protected] 

If after checking points described in chapter 6.1 “Faults identification and repair” and the unit still does not work 
properly, Please Contact Technical Service @ IGLOO Refrigeration. 

Содержание JSCRP

Страница 1: ...Pastry Display Cases Models JSCRP and J2SCRP JSCRP J2SCRP Instruction Manual Tel 416 663 3051 Fax 416 663 5793 Toll Free 1 888 408 8819 124 Norfinch Dr Toronto ON M3N 1X1 REFRIGERATION LTD...

Страница 2: ...Temperature regulation 8 5 MAINTENANCE 9 5 1 Cleaning and maintenance 12 6 SERVICE 13 6 1 Faults identification and repair 13 6 2 Service 14 List of Figures Figure 1 JSCRP and J2SCRP 4 Figure 2 Level...

Страница 3: ...n the environment and the location of the unit 2 2 Description of the unit JSCRP and J2SCRP display cases have static cooling The display case is equipped with automatic condensate evaporation and aut...

Страница 4: ...louver 10 ABS sides 11 Control panel 12 Condenser cover DO NOT BLOCK air louver 13 Leveling legs 14 Serial plate 15 Straight front glass 2 3 Technical data Table 1 Technical data Model Voltage V Hz Ph...

Страница 5: ...y be turned on after confirmation of the fire protection efficiency with results of measures performed according to binding regulations 3 2 Unit Location Remove cardboard angles and protective foil In...

Страница 6: ...disassembled If the user received the unit partially disassembled perform the following operations 1 Place the Fixed shelf grip in perforated frame strip Figure 3 5 2 Mount cross bars Figure3 3 and Fi...

Страница 7: ...d aggregate operating cycle may fluctuate This depends on numerous factors such as amount and temperature of products placed in the device and the temperature of the surroundings The equipment should...

Страница 8: ...ranty Do not use electric devices inside the product storing chamber Avoid unnecessary opening of doors and leaving them open for a longer period of time 4 1 Temperature regulation The thermostat is t...

Страница 9: ...1 sec displays sets the set point more than 3 sec accesses the parameter setting menu enter password 22 mutes the audible alarm buzzer Start Up hold the set mute button for 1 sec RESET current EY set...

Страница 10: ...e category of parameters will be on Press SET to display the value associated with the parameter Increase or decrease the value using the UP or DOWN button respectively Press SET to temporarily save t...

Страница 11: ...absolute relative temperature for low temperature alarm 0 0 C 50 99 AH absolute relative temperature for high temperature alarm 0 0 C 50 99 Ad temperature alarm delay 0 min 0 199 A4 3rd input configur...

Страница 12: ...attention not to damage the temperature sensor It is recommended to make a break in the operation once a month in order to clean the interior naturally defrost the evaporator and clean the condenser I...

Страница 13: ...equipment is not working Make sure that The equipment is connected to the power supply The Voltage and frequency in the network are compliant with those recommended by the manufacturer 115V 60Hz The m...

Страница 14: ...Each compressor makes certain noises when operating These sounds are made by the aggregate engine and by cooling agent flowing through the circuit This phenomenon constitutes a technical feature of co...

Отзывы: