7. THERMOSTAT SERVICE

7.1. „IGLOO” thermostat

Fig.13 „Igloo” thermostat control panel

Verification of adjusted temperature (inside the device) – By pressing “▲” or “▼” switch once we can verify the adjusted 

temperature. The adjusted temperature shall be shown on the display with a visible red blinking spot (diode). The preview 

shall finish automatically after about  3 seconds. 

Lowering (or increasing) the temperature – press “▼” (or “▲”) switch and the adjusted temperature shall be visible on 

control panel. By pressing the “▼” switch we decrease the temperature to the desired value. The preview shall finish 

automatically after about  3 seconds.

Manual defrosting – switch No. 2 enables to initiate the defrosting cycle at any moment when the device is working (re-

gardless of the automatic defrosting function); the switch shall not operate when the temperature is higher than the final 

defrosting temperature.

The user should switch on/ switch off the aggregate only by means of the main switch of the device, and 

not by means of the direct switch on thermostat control panel. Switching on the main switch shall automa-

tically initiate the thermostat!

* Read more on www.igloo.pl

1 – Cooling on/off switch 

2 – Manual defrosting switch

3 – Aggregate and defrosting operating control diode

4 – Temperature monitoring switch on defrosting sensor

5 – Temperature regulation switch (increase)

6 – Temperature regulation switch (decrease)

2

1

3

4

6

5

Содержание Jamajka W OPEN

Страница 1: ...rmostat optionally working with the temperature recording module which allows for recording and signaling whenever the temperature in the unit is too high or too low Cooling is done by forced air circulation The cabinet is equipped with automatic condensate evaporation and automatic defrosting It is suitable for connecting in rows and can be supplied with an external chiller unit mod C The display...

Страница 2: ...indchest After removing access to the condenser fins is available DO NOT OBSTRUCT THE VENTS 2 3 Technical data Table 1 Technical data Type of unit Rated voltage V Hz Rated current A Rated lighting power W Power consumption kWh 24h Shelf load kg m Cooling po wer demand W mb Unit weight kg 1 3W Open 230 50 4 7 144 16 2 10 190 1 3W Open mod A 230 50 4 7 144 16 2 10 180 1 3W Open mod C 230 50 144 10 7...

Страница 3: ...r and the unit s components Any residual adhesive or silicon on metal components may only be removed with petroleum ether does not apply to plastics compo nents Do not use other organic solvents Do not use water jets while washing the unit The unit should be cleaned with a damp cloth Place the plug of the connection cable directly into the socket it is forbidden to connect the device via extension...

Страница 4: ...ngle Fig 4 Assembly disassembly of glass elements 1 Glass side 2 Front glass grip 3 Low front glass 4 Top aluminum profile tilting guide of the glass 5 Frame display shelf 6 Countertop display shelf 7 Bumpon silicone element protecting glass components from moving and providing better grip Do not damage during operation and maintenance 8 Frame hook 1 1 5 260 6 440 530 525 7 8 2 2 2 1 3 3 4 4 Fig 6...

Страница 5: ... around the unit in any case do not cover the vents t Ensure a uniform load on the shelves without exceeding their maximum load Keeping the condenser clean Impurities may cause overheating of the compressor and ultimately lead to failure which is not covered by the warranty Do not use electrical appliances inside the chamber for storing food products 4 1 Temperature control For operation of thermo...

Страница 6: ...pressor unit To clean the condenser unscrew the fixing screws and remove the windscreen Clean the condenser fins with a soft brush For strong soiling clogging the fins of the condenser it is advisable to use a vacuum or compressed nitrogen to suck out blow out the soil from between the fins Fig 10 Condenser cleaning The manufacturer is not liable for damage to the condensing unit resulting from no...

Страница 7: ...erns the Igloo thermostat If only two spots are visible on the display turn on the thermostat The device is operating but the lighting is off Make sure that Lighting switch is turned on Fluorescent lamp or starting switch of the device is not burnt The device does not reach the proper temperature the lighting is on Make sure that The main switch is on Temperature setting on the thermostat is prope...

Страница 8: ...f automatically Every compressor produces a noise while at work These sounds are generated by the motor unit and by the refrigerant flowing in the circuit This pheno menon is a technical characteristic of refrigeration units and does not mean malfunction In the case of exceeding the ambient conditions as per third class climate relative humidity above 60 the phenomenon of water transfer from the s...

Страница 9: ...nish automatically after about 3 seconds Manual defrosting switch No 2 enables to initiate the defrosting cycle at any moment when the device is working re gardless of the automatic defrosting function the switch shall not operate when the temperature is higher than the final defrosting temperature The user should switch on switch off the aggregate only by means of the main switch of the device an...

Страница 10: ...d 5 current temperature inside the device is displayed decimal places displayed after the comma SETTING THE DESIRED TEMPERATURE press for 1 second leading value shall be displayed on the screen increase or decrease the leading value by means of and switches until the desired value shall be obtained press once again in order to confirm the new value of the setting point MANUAL INPUT OF THE DEFROSTI...

Отзывы: