Fig.8 Replacing the fluorescent lamp

1 – Lamp grip

2 – Lamp

3 – Light housing

4 – Fluorescent igniter

During maintenance work, be careful not to damage the nameplate Fig.9 (p.13), which contains 

important information for maintenance workers and waste disposal companies.

6. SERVICE

6.1. Fault identification and repair

In case of any difficulties during actuation of the device or during its exploitation, please return to these chapters in this 

manual, which explain the performed operation. This aims to ensure that the device is properly operated. If you still 

experience difficulties, the following hints will help you solve the problem:

The device is not working... – Make sure that:

•  The device is connected to the supply network

•  Voltage and frequency in the network are compliant with those recommended by the producer, 230V/50Hz

•  The main switch is turned on

•  Thermostat is turned on (This concerns the Igloo thermostat – If only two spots are visible on the display – turn on 

the thermostat)

The device is operating, but the lighting is off...– Make sure that:

•  Lighting switch is turned on

•  Fluorescent lamp or starting switch of the device is not burnt

The device does not reach the proper temperature, the lighting is on...– Make sure that:

•  The main switch is on

•  Temperature setting on the thermostat is properly set

•  Thermostat works properly

•  The condenser is clean, if necessary – clean the condenser

•  Ambient temperature does not exceed 25ºC 

•  Enough time has passed for products to be cooled

•  Ventilation holes of the device are not blocked

(This concerns the “IGLOO” thermostat) thermostat displays C0 or C1 or C2 instead of displaying temperature:

This situation shall occur, when one of temperature regulation sensors has been destroyed. The following 

messages may be displayed in such case:

•  C0 – temperature sensors inside the chamber are damaged – call authorized service

•  C1 – failure of evaporator sensor - call authorized service

•  C2 – failure of condenser alarm sensors (or failure of second evaporator sensor) – call authorized service

3

4

2

1

Содержание Jamajka W OPEN

Страница 1: ...rmostat optionally working with the temperature recording module which allows for recording and signaling whenever the temperature in the unit is too high or too low Cooling is done by forced air circulation The cabinet is equipped with automatic condensate evaporation and automatic defrosting It is suitable for connecting in rows and can be supplied with an external chiller unit mod C The display...

Страница 2: ...indchest After removing access to the condenser fins is available DO NOT OBSTRUCT THE VENTS 2 3 Technical data Table 1 Technical data Type of unit Rated voltage V Hz Rated current A Rated lighting power W Power consumption kWh 24h Shelf load kg m Cooling po wer demand W mb Unit weight kg 1 3W Open 230 50 4 7 144 16 2 10 190 1 3W Open mod A 230 50 4 7 144 16 2 10 180 1 3W Open mod C 230 50 144 10 7...

Страница 3: ...r and the unit s components Any residual adhesive or silicon on metal components may only be removed with petroleum ether does not apply to plastics compo nents Do not use other organic solvents Do not use water jets while washing the unit The unit should be cleaned with a damp cloth Place the plug of the connection cable directly into the socket it is forbidden to connect the device via extension...

Страница 4: ...ngle Fig 4 Assembly disassembly of glass elements 1 Glass side 2 Front glass grip 3 Low front glass 4 Top aluminum profile tilting guide of the glass 5 Frame display shelf 6 Countertop display shelf 7 Bumpon silicone element protecting glass components from moving and providing better grip Do not damage during operation and maintenance 8 Frame hook 1 1 5 260 6 440 530 525 7 8 2 2 2 1 3 3 4 4 Fig 6...

Страница 5: ... around the unit in any case do not cover the vents t Ensure a uniform load on the shelves without exceeding their maximum load Keeping the condenser clean Impurities may cause overheating of the compressor and ultimately lead to failure which is not covered by the warranty Do not use electrical appliances inside the chamber for storing food products 4 1 Temperature control For operation of thermo...

Страница 6: ...pressor unit To clean the condenser unscrew the fixing screws and remove the windscreen Clean the condenser fins with a soft brush For strong soiling clogging the fins of the condenser it is advisable to use a vacuum or compressed nitrogen to suck out blow out the soil from between the fins Fig 10 Condenser cleaning The manufacturer is not liable for damage to the condensing unit resulting from no...

Страница 7: ...erns the Igloo thermostat If only two spots are visible on the display turn on the thermostat The device is operating but the lighting is off Make sure that Lighting switch is turned on Fluorescent lamp or starting switch of the device is not burnt The device does not reach the proper temperature the lighting is on Make sure that The main switch is on Temperature setting on the thermostat is prope...

Страница 8: ...f automatically Every compressor produces a noise while at work These sounds are generated by the motor unit and by the refrigerant flowing in the circuit This pheno menon is a technical characteristic of refrigeration units and does not mean malfunction In the case of exceeding the ambient conditions as per third class climate relative humidity above 60 the phenomenon of water transfer from the s...

Страница 9: ...nish automatically after about 3 seconds Manual defrosting switch No 2 enables to initiate the defrosting cycle at any moment when the device is working re gardless of the automatic defrosting function the switch shall not operate when the temperature is higher than the final defrosting temperature The user should switch on switch off the aggregate only by means of the main switch of the device an...

Страница 10: ...d 5 current temperature inside the device is displayed decimal places displayed after the comma SETTING THE DESIRED TEMPERATURE press for 1 second leading value shall be displayed on the screen increase or decrease the leading value by means of and switches until the desired value shall be obtained press once again in order to confirm the new value of the setting point MANUAL INPUT OF THE DEFROSTI...

Отзывы: