8. Faults, Troubleshooting and Customer Service
8.1 Fault analysis and actions
In the event of damage, cordon off the danger zone over a wide area!
Always exercise caution as severe burns may be sustained over the
whole body
Fault
Cause
Action
Possible
troubleshooting
Leakage
- glass/mica break
- packing set not tight
- seal not tight
1. Close shutoff
valves
2. Slowly open drain
valve
(Depressurise
gauge)
- replace glass/mica
shield
- replace packing set /
seal
- retighten screw
connections
No water
column
visible in
the gauge
- shutoff valves are
not open
- inlet or outlet pipe is
blocked
- connection bores in
the gauge are
blocked
1. Close shutoff
valves
2. Slowly open drain
valve
(Depressurise
gauge)
- carefully open shutoff
valves.
- clean inlet and outlet
pipes
- clean gauge
To put the level gauge back into operation, see section 8.
8.2 Technical customer service
Our competent team at IGEMA GmbH will be happy to answer any questions you may have.
In order to be able to ensure smooth service, please provide the following details:
•
Date of manuf order number
•
Device type
You can find the details on the type plate of your gauge. As soon as you have described your
question or fault, our customer service will immediately seek a solution. If repairs or
maintenance are due, we shall make you a proposal for the type and date for the work.