14
Output (PLC)
External inputs
<input name>
Real
4 bytes
Set value of the external input (Exter-
nal_xx)
Objects
<object name>
Base line
Real
4 bytes
Limits - set base line in SI unit (m/s², m/s,
m) to adapt the limits
General
Variant
Byte
1 byte
Set current variant (0���31)
Do self-test
Byte
1 byte
Do self-test (≠ 0)
Set time
DINT
4 bytes
Set time, always UTC, format:
- VSE150: U32: 0x00ssmmhh
- VSE151: U32: 0x00hhmmss
- VSE152: U32: 0x00hhmmss
- VSE153: U32: 0x00hhmmss
Set counter ID
Byte
1 byte
Set ID (1���32) of the counter
Set counter value
DINT
4 bytes
Set value of the counter selected with the
ID (in seconds)
8.3 Supported communication types
Requirement
Parameters
Explicit messaging
Based on the request/response principle
(e�g� use for device configuration)
Message Protocol: TCP
Implicit messaging
Based on the producer/consumer model
(e�g� cyclic transmission of I/O data)
Message Protocol: UDP
8.4 CIP object classes
The device supports the following CIP object classes:
Class ID
Object
0x01
Identity
0x02
Message Router
0x04
Assembly
0x06
Connection Manager
0x47
Device Level Ring (DLR)
0x48
Quality of Service (QoS)
0xF5
TCP/IP Interface
0xF6
Ethernet Link