![IFM VNB211 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/ifm/vnb211/vnb211_operating-instructions-manual_4169149021.webp)
21
UK
Sub-menu external characteristic vibration values EV1) and EV2) with respective
configuration
ESP1
Switch point pre-alarm
If the switch point is exceeded,
-OU1 switches, if it is digital
-the yellow LED "OU1" lights
-the measured value display changes to yellow
ESP2
Switch point main alarm
If the switch point is exceeded,
-OU2 switches
-the red LED "OU2" lights
-the measured value display changes to red
AUER
Averaging → chapter 6.5
Sub-menu external characteristic vibration values EP1) and EP2) with respective
configuration
ESP1
Switch point pre-alarm
If the switch point is exceeded,
-OU1 switches, if it is digital
-the yellow LED "OU1" lights
-the measured value display changes to yellow
Eh1
Hysteresis pre-alarm
Absolute distance between set and reset point
ESP2
Switch point main alarm
If the switch point is exceeded,
-OU2 switches
-the red LED "OU2" lights
-the measured value display changes to red
Eh2
Hysteresis main alarm
Absolute distance between set and reset point
Sub-menu external input as analogue current input
EASP
Scaling of external sensor for the process value,
initial value of the measuring range at 4 mA
EAEP
Scaling of external sensor for the process value,
final value of the measuring range at 20 mA
Sub-menu outputs
ou1
Switching logic OU1 (OU1 = digital)
NC, NO (normally closed, normally open)