20
9.3 Explanation of the menu
Menu level 1
V1 )
Sub-menu for the characteristic vibration value 1
V2 )
Sub-menu for the characteristic vibration value 2
EV1)
Sub-menu for the external characteristic vibration value 1 with respective
configuration
EV2)
Sub-menu for the external characteristic vibration value 2 with respective
configuration
EP1)
Sub-menu for the external process value 1
EP2)
Sub-menu for the external process value 2 with respective configuration
EXT)
Sub-menu for the external input
in the configuration as analogue input
OUT)
Sub-menu for the outputs
Uni
Unit of the vibration velocity - mm/s or in/s
Test
Self-test - (PASS or FAIL)
is automatically made when the sensor is switched on
Sub-menu characteristic vibration values V1) and V2)
The values indicated for the switch points SP1 and SP2 of characteristic values of the
vibration velocity change when another unit is selected�
SP1
Switch point pre-alarm
If the switch point is exceeded,
-OU1 switches, if it is digital
-the yellow LED "OU1" lights
-the measured value display changes to yellow
SP2
Switch point main alarm
If the switch point is exceeded,
-OU2 switches
-the red LED "OU2" lights
-the measured value display changes to red
AUER
Averaging → chapter 6.5