7
UK
4 Function
• The volumetric flow is monitored by a calorimetric measuring system, the
measured signals are evaluated by the electronics�
• The unit detects the media temperature of the volumetric flow as additional
process value�
• The unit features an IO-Link interface
• The unit displays the current process values�
• The unit has many self-diagnostic options�
• A simulation mode allows simplified set-up of the sensor�
4.1 Processing of the measured signals
The unit generates 2 output signals according to the parameter setting:
OUT1: 6 selection options
-switching signal for volumetric flow quantity limit
-switching signal for temperature limit
-switching signal for preset counter
-pulse signal for quantity meter
-IO-Link
-OFF (output switched to high impedance)
OUT2: 8 selection options
-switching signal for volumetric flow quantity limit
-switching signal for temperature limit
-switching signal for preset counter
-switching signal for quantity meter
-analogue signal for volumetric flow quantity
-analogue signal for temperature
-input for external counter reset signal (InD)
-OFF (output switched to high impedance)