15
UK
4.9 IO-Link
This unit has an IO-Link communication interface which enables direct access to
process and diagnostic data� In addition it is possible to set the parameters of the
unit while it is in operation� Operation of the unit via an IO-Link interface requires
an IO-Link master�
With a PC, suitable IO-Link software and an IO-Link adapter cable communication
is possible when the system is not in operation�
The IODDs necessary for the configuration of the unit, detailed information about
process data structure, diagnostic information, parameter addresses and the
necessary information about the required IO-Link hardware and software can be
found at www�ifm�com�
4.9.1 Additional functions via IO-Link
The following functions are only available via the IO-Link interface by means of a
parameter setting software:
Flash on /
Flash off
Standard command for localising the sensor in the system�
When activated:
> switching status indicating LEDs are flashing
> display: "IO-Link" (green, flashes)
5 Installation
CAUTION!
If the medium temperature is above 50 °C (122 °F), parts of the
housing can increase in temperature to over 65 °C (149 °F)�
> Risk of burns�
►
Protect the housing against contact with flammable substances
and unintentional contact�
►
Apply the supplied warning label to the sensor cable�
►
Ensure that the system is free of pressure during installation�
►
The rules and regulations for the installation and operation of com-
pressed air equipment must be observed�