UK
• Change from menu level 1 to menu level 2:
►
Press [Mode/Enter] until [EF] is
displayed
.
If the submenu is protected with an
access code, [cod1] is displayed�
►
Press [Set] and keep it pressed until
the valid code no� is displayed�
►
Briefly press [Mode/Enter]�
When delivered by ifm electronic: no
access restriction�
►
Briefly press [Set]�
> The first parameter of the submenu is
displayed (here: [rES])�
• Locking / unlocking
The unit can be locked electronically to prevent unintentional settings� Locking
is also possible via an IO-Link capable parameter setting tool�
►
Make sure that the unit is in the
normal operating mode�
►
Press [Mode/Enter] + [Set] for 10 s�
> [Loc] is displayed�
During operation: [Loc] is displayed for 15 s if you try to change parameter values�
For unlocking:
►
Press [Mode/Enter] + [Set] for 10 s�
> [uLoc] is displayed�
On delivery: not locked�
• Timeout:
If during parameter setting no pushbutton is pressed for 15 s, the unit exits the
parameter setting mode�