10
9 Parameter setting
During parameter setting the unit remains in the operating mode It continues its
monitoring function with the existing parameters until the parameter setting has
been completed
9.1 General parameter setting
3 steps must be taken for each parameter setting:
1
Parameter selection
►
Press [Mode/Enter] until the
requested parameter is displayed
.
2
Setting of the parameter value
►
Press [Set] and keep it pressed
> Current setting value of the
parameter flashes for 5 s
> After 5 s: Setting value is changed:
incrementally by pressing the button
once or continuously by keeping the
button pressed
Numerical values are incremented continuously To reduce the value: let the display
move to the maximum setting value Then the cycle starts again at the minimum
setting value
3
Acknowledgement of the parameter
value
►
Press [Mode/Enter] briefly
> The parameter is displayed again
The new setting value is stored
Setting of other parameters
►
Start again with step 1
Finishing the parameter setting
►
Press [Mode/Enter] several times until the current measured value is displayed or wait
for 5 s
> The unit returns to the operating mode