13
UK
9 Parameter setting
During the parameter setting process the unit remains in the operating mode�
It continues its monitoring function with the existing parameters until parameter
setting has been terminated�
9.1 Parameter setting general
Each parameter setting requires 3 steps:
1
Selecting parameter
►
Press [Mode/Enter] until the
requested parameter is displayed�
Mode/Enter Set
2
Setting the parameter value
►
Press [Set] and keep the buton
pressed�
> Current setting value of the
parameter bit flashes for 5 s�
> After 5 s: Setting value is changed:
incremental by pressing briefly or
scrolling by holding pressed�
Mode/Enter Set
The numerical values are incremented continuously� If the value is to be reduced: Let
the display move to the maximum setting value� Then the cycle starts again at the
minimum setting value�
3
Acknowledge parameter value
►
Press [Mode/Enter] briefly�
> The parameter is displayed again�
The new setting value is stored�
Mode/Enter Set
Set more parameters
►
Start again with step 1�
Finishing parameter setting
►
Press [Mode/Enter] several times until the current measured value is displayed or wait
for 15 s�
> The unit returns to the operating mode�