11 Parameter setting
During parameter setting the unit remains internally in the operating mode. It continues its monitoring
function with the existing parameters until the change has been completed.
For the factory settings please refer to the end of these instructions. Factory setting (
40).
11.1 Parameter level basic functions
In the parameter level basic functions the following parameters can be selected:
11.1.1 [Adjust threshold]
Set the switching threshold
u
Confirm the parameter with [●] and set the switching threshold to the desired value using [▲ / ▼].
u
Confirm the value with [●].
w
The new switching value is confirmed. (→ 8.1.5 Schaltschwelle)
11.1.2 [ROI marking]
Activate/deactivate the indication of the ROI markings on the laser line
If a [Fixed] position of the reference profile has been selected during teaching, the ROI
markings show the ROI defined during teaching. If a [Floating] position has been selected, the
ROI markings indicate the entire operating range. Set the position of the reference profile
(
u
Confirm the parameter with [●] and select one of the options [No] / [Yes] using [▲ / ▼].
u
Confirm your selection by pressing [●].
w
Depending on the setting made, the green ROI markings on the laser line are activated/
deactivated.
The marking lines are automatically switched off after about 10 minutes.
For reactivation:
u
Reset parameters.
11.1.3 [Profile properties]
Reading the status parameter
u
Confirm the parameter with [●].
w
The current value of the status parameter is displayed.
11.1.4 [Profile manager]
Control of the reference profiles
u
Confirm parameter with [●] and select one of the three options [Select active profile], [Add new
profile] or [Delete profile] using [▲ / ▼].
[Select active profile]:
u
Confirm the parameter with [●].
GB