OPD101
19
w
The request [Place object and press confirm] is displayed.
w
The sensor emits a red laser line with two vertical green ROI markings.
u
Place the sensor so that the laser line covers the area to be monitored and the object is within the
operating range of 150...300 mm. General representation (
u
Start the teaching process by pressing [●].
w
The sensor repeatedly measures the profile of the object/background.
u
Select [Confirm] or [Back] using [▲] / [▼] and press [●].
•
[Confirm]: Taught profile is saved.
•
[Back]: Teach the profile again.
The object should not be moved during measurement. The end of the measurement is not only
indicated in the display, but also via the laser line flashing twice.
If the object to be detected is outside the operating range (e.g. closer than 150 mm or farther
away than 300 mm), the teaching process is stopped. The message [Object out of range]
appears for three seconds. Afterwards, a new teaching process is started.
8.1.3 Set ROI
The sensor makes it possible to select an ROI from the entire taught height profile. The profile section
included in this ROI is saved as reference profile and used to determine the matching value.
Based on this restriction, the assessment of the height profile can be limited to the relevant
section. Deviations regarding other, irrelevant sections are not taken into account.
When operating with the “Vision Assistant” parameter setting software, it is possible to define up
to two profiles (ROIs).
u
In the next step, the ROI is set.
w
The options [Define ROI] and [Back] are displayed.
u
Select [Define ROI] or [Back]or using [▲] / [▼] and press [●].
•
[Define ROI]: Define an ROI from the entire profile taught.
•
[Back]: Teach the profile again.
u
Select [Define ROI] using [● ].
w
[Set left ROI mark] is displayed.
u
Move the green marking line using [▲] / [▼].
w
The left marking line shifts.
u
After reaching the requested position, confirm with [●].
w
The position of the left marking line is set.
w
The selected section is detected again (new profile).
w
[Set right ROI mark] is displayed.