1  Preliminary note

Technical data, approvals, accessories and further information at 
www.ifm.com.

2  Safety instructions

•  Read this document before setting up the product and keep it during the entire 

service life.

•  The product must be suitable for the corresponding applications and 

environmental conditions without any restrictions.

•  Only use the product for its intended purpose (→ Functions and features).
•  If the operating instructions or the technical data are not adhered to, personal 

injury and/or damage to property may occur. 

•  The manufacturer assumes no liability or warranty for any consequences 

caused by tampering with the product or incorrect use by the operator.

•  Installation, electrical connection, set-up, operation and maintenance of the 

product must be carried out by qualified personnel authorised by the machine 
operator.

•  The plant operator is responsible for the safety of the plant in which the device 

is installed.

•  If the device is not used as intended by the manufacturer, the protection 

supported by the device may be impaired.

•  Protect units and cables against damage.

2.1  Symbols used

Instruction

Cross-reference
Important note
Non-compliance may result in malfunction or interference.
Information
Supplementary note.

Содержание MVQ101

Страница 1: ...Device manual Valve sensor MVQ101 80270936 00 04 2018 UK...

Страница 2: ...y may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator Installation electrical connection set up opera...

Страница 3: ...h the standard EN 61000 6 4 The unit may cause radio interference in domestic areas The user must take appropriate measures to avoid this interference if necessary 1 2 3 1 Use the two notches at the b...

Страница 4: ...pin 4 Communication IO Link Switching output valve position open in SIO mode OUT 2 pin 2 Switching output valve position closed OUT 3 pin 5 Programmable Switching output valve position open Switching...

Страница 5: ...ctory red flashing fault in the unit no pulse pick up available teach error switch points SSC1 and SSC2 overlap end position not reached after set time has elapsed unit faulty The LED colours in the t...

Страница 6: ...ble Reading current process values Reading changing and saving current parameter settings and transmitting them to other units of the same type Connect the unit via the IO Link interface to a PC or PL...

Страница 7: ...lerance and hysteresis can be set separately for each switch point with an additional seal monitoring for SSC2 9 3 2 Parameter setting via inductive teach button The sensor is adjusted using a metal o...

Страница 8: ...ch button approx 20 s until the LED ring briefly flashes once 10 Settings 2 2 1 Settings tolerance Set a tolerance range between 0 1 and 15 around the taught set switch point 1 Teach point 2 Tolerance...

Страница 9: ...Tolerance width 10 1 Timeout Timeout indicates the maximum duration for closing or opening before the sensor signals a blockage Adjustable time between 0 1 30 s factory setting 30 s In parallel the p...

Страница 10: ...Defect of the unit Puck not used Limit value for the timeout exceeded 10 4 Opening closing duration The minimum maximum closing opening duration of the drive can be freely set and monitored The sensor...

Отзывы: