UK
Ethernet camera O2M113
7
5 Electrical connection
5.1 Ethernet camera
Supply voltage (1)
M12 connector, A-coded, 4 poles
1
2
3
4
8 . . .32 V DC
n .c .
0 V
n .c .
Ethernet (2)
M12 socket, D-coded, 4 poles
1
2
3
4
Ethernet TxD +
Ethernet RxD +
Ethernet TxD -
Ethernet RxD -
For information about available connectors please go to:
www .ifm .com
→ Products → Accessories → Connection technology → Selector
The supply voltage is electrically separated from the housing .
5.1.1 Ethernet connection
►
Use a shielded CAT5 cable .
(STP, Shielded Twisted Pair, according to EIA/TIA-568) . Max . length 100 m
►
Use screened connector housings
►
Connect the screen of the Ethernet cable to the connector housing .
►
Avoid transmission problems caused by induction .
►
Do not lay the Ethernet connection cable in parallel to current-carrying cables .
►
Lay supply and signal cables away from the camera using the shortest possible
route .
5.1.2 Interference due to external influences
Faulty or insufficient radio interference suppressors in electrical equipment,
such as inverters or generators, as well as voltage fluctuations when
switching on/off electric loads may lead to problems with the image
transmission .