• The sensor continually monitors and adjusts to the medium. Thus it
adapts itself to different media and compensates for changes in the
medium.
• For water and hydrous media with temperatures > 35°C install the
unit into the climatic tube (order no. E43100, E43101, E43102).
The sensor is not suitable for:
• Very conductive and adhesive media (shampoo, toothpaste, glue,
etc.).
• Dry granulated materials with low density.
• Media which are very inhomogeneous, separate from each other
thus forming separation layers (e.g. oil layer on water which is sever-
al cm thick or a water layer at the bottom of a vessel filled with oil).
Note: A thin oil film (a few mm) on water or water based media
does not affect the function of the sensor.
Applications
Measuring range
Page 22
Function and features
A
L
I
min
OFS
max
min
max
LK8024
LK8023
LK8022
cm
26.4
47.2
72.8
10.4
18.6
28.7
L = probe length
inch
cm
19.5
39.0
58.5
7.7
15.4
23.0
A = active zone/ measuring range
inch
cm
5.3
5.3
10.2
2.0
2.0
4.0
I
= inactive zone
inch
cm
1.5*
3.0*
4.0*
0.6*
1.2*
1.6*
min = lowest measured value
inch
cm
21.0*
42.0*
62.0*
8.3*
16.6*
24.4*
max = highest measured value
inch
cm
0 ... 78.0
0 ... 57.0
0 ... 186
0 ... 30.7
0 ... 22.5
0 ... 73.2
OFS = offset
inch
*With offset > 0 the OFS value is added to these values.
factory setting: OFS = 0
measur
ed /
display
value