10
8 Operation
8.1 Operation of the IO-Link version
8.1.1 General
The unit is connected to an IO-Link master (A port) with a 4-pole connection cable�
The controller switches the individual LED segments on and off in the configured
colours according to the set parameters�
Via the parameter "Operating mode" the following modes can be set:
• On/off mode
• RGB mode
• Analogue mode
8.1.2 On/off mode
While in operation, the controller switches the 5 LED segments and the buzzer
(only with DVx510 and DVx530) on and off (PDout, cyclical data communication)�
Signalling corresponds to the pre-defined parameters for the individual LED
segments and the buzzer�
Via the acyclic parameter setting the following properties can be set for every LED
segment:
• Colour (red, green, orange, blue, violet, turquoise, white, yellow, off)
• Frequency (permanently on, low flash rate slow/medium/fast, high flash rate
slow/medium/fast)
• Brightness (100 %, 75 %, 50 %, 25 %)
For the models with an acoustic signal device the audibility of the buzzer can be
set�
7
6
5
4
3
2
1
0
PDout
Seg� 5
Seg� 4
Seg� 3
Seg� 2
Seg� 1
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Buzzer sound (buzzer style
1���8)
Buzzer
Byte 5