background image

DTI424 DTI425

16

Status bit

Value

Description

Cmd End

1

Read or write operation terminated

Cmd Start Acknowledge

0

Start of a read or write operation not acknowledged

1

Start of a read or write operation acknowledged

Cmd Antenna deactivate

0

Activate antenna

1

Deactivate antenna

Cmd Start

0

Reset trigger for read or write operation

1

Set trigger for read or write operation

The following status bits cannot be used in the "Read UID" operating mode:

u

Cmd Start

u

Cmd Start Acknowledge

u

Cmd End

Содержание DTI424

Страница 1: ...Operating instructions RF identification system DTI424 DTI425 Read write head 11424519 00 09 2022 GB...

Страница 2: ...9 1 Parameter 14 9 1 1 Data block size 14 9 1 2 Data alignment 14 9 1 3 Data hold time 14 9 1 4 Address for automatic read write 15 9 1 5 Data length for automatic read write 15 9 2 Status bits 15 10...

Страница 3: ...ss reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used ATTENTION Warning of damage to property 1 3 Legal and copyright in...

Страница 4: ...nded purpose Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty f...

Страница 5: ...DTI424 DTI425 5 3 Intended use The read write head reads and writes ID tags without contact The data is made available as process data via the IO Link interface...

Страница 6: ...plied Read write head 2x hexagonal nut The device is supplied without installation and connection accessories Available accessories www ifm com The optimum function is not ensured when using component...

Страница 7: ...Article number DTI424 Function Read write head Type designation DTRHF GBRWIOUS03 Type M18 flush mountable DTI425 Article number DTI425 Function Read write head Type designation DTRHF GNRWIOUS03 Type M...

Страница 8: ...device generates a modulated electrical field with a frequency of 13 56 MHz Avoid interference with data communication u Do not operate any devices in the vicinity that use the same frequency band w...

Страница 9: ...device u Fix the device using the supplied nuts M18 DTI424 Fig 3 Flush mounting DTI425 Fig 4 Non flush mounting 6 5 Mounting distances DTI424 Operating mode Distance side A Distance front B For readi...

Страница 10: ...ign the axes of the RFID device and the ID tag in the same way For installation in or on metal use the ID tags provided for this purpose Position the ID tag in the area of the sensing face When doing...

Страница 11: ...D Fig 6 Position the ID tag u Align the ID tag on the central axis of the antenna of the unit ID tag Type Distance read write head D in plastic E80371 40 mm The indications in the table apply to stati...

Страница 12: ...III The electrical supply must only be made via PELV SELV circuits u Disconnect power before connecting the device 7 1 Wiring u Connect the device to an IO Link master using the M12 connector w Voltag...

Страница 13: ...ltage OK off operating voltage missing flashing slowly deactivated yellow on permanently ID tag detected on pulse ID tag read written successfully flashing quickly error when reading writing on ID tag...

Страница 14: ...ignment The parameter sets the order of the data in a data block of the ID tag Example For an ID tag with block size 4 bytes the data can be ordered as in the tables Data block 0 Data block 1 Byte 3 B...

Страница 15: ...and written The length is indicated in bytes The minimum length is 1 byte and the maximum length is 29 bytes In the operating modes Auto read and Auto write the device reads and writes a specified num...

Страница 16: ...on not acknowledged 1 Start of a read or write operation acknowledged Cmd Antenna deactivate 0 Activate antenna 1 Deactivate antenna Cmd Start 0 Reset trigger for read or write operation 1 Set trigger...

Страница 17: ...next to each other is reduced by deactivating the antenna Deactivate the internal antenna u Set the Cmd Antenna deactivate bit in the process data output The status of the internal antenna is queried...

Страница 18: ...length of 29 bytes the data remaining in the process image is filled with the value 0x00 The data in the process image is updated as soon as an ID tag enters the detection range The data in the proce...

Страница 19: ...ta In the operating mode Auto write data the data to be written is defined by the process data output image The data is set with the parameters Address for Auto Read Write and Data Length for Auto Rea...

Страница 20: ...a 3 6 Data 4 Data 4 7 Data 5 Data 5 8 Data 6 Data 6 9 Data 7 Data 7 10 Data 8 Data 8 11 Data 9 Data 9 12 Data 10 Data 10 13 Data 11 Data 11 14 Data 12 Data 12 15 Data 13 Data 13 16 Data 14 Data 14 17...

Страница 21: ...t two steps are repeated until all data has been transferred w The device sets the status bit Cmd End with the last transfer The read operation is terminated If reading was unsuccessful the device set...

Страница 22: ...e data 0x03 0x0012 0x0023 0x00 0x00 1 Controller ac knowledges re ceipt of the data 0x03 0x0012 0x0023 0x00 0x01 1 Device sets more data and terminates read ing 0x03 0x0012 0x0023 0x00 0x01 1 Controll...

Страница 23: ...ccessful Command value Address Length Data 0 to 27 Block counter Status bit Cmd Start Preset com mand 0x00 0x0000 0x0000 0x00 0x00 0 Controller sets command read 35 bytes from address 0x12 0x03 0x0012...

Страница 24: ...ess 16 bits and the data length 16 bits u With the control start the write operation with the status bit Cmd Start w The device acknowledges the start of the write operation by setting the status bit...

Страница 25: ...0x00 20 ignored Data 18 0x00 21 ignored Data 19 0x00 22 ignored Data 20 0x00 23 ignored Data 21 0x00 24 ignored Data 22 0x00 25 ignored Data 23 0x00 26 ignored Data 24 0x00 27 ignored Data 25 0x00 28...

Страница 26: ...Status bit Cmd End Status bit Cmd Start Preset com mand 0x00 UID 0x00 0x00 0 0 Controller sets command write 40 bytes to ad dress 0x10 0x04 UID 0x00 0x00 0 0 Device acknowl edges com mand 0x04 0x00 0...

Страница 27: ...0x02 1 Controller with draws com mand value 0x00 0x0000 0x0000 0x00 0x00 0 Device carries out preset com mand 0x00 0x0000 0x0000 0x00 0x00 0 Tab 9 Process data output Command value Data 0 to 27 Block...

Страница 28: ...ring reception of the data of the ID tag 0x21 TAG_COMMAND_NOT_SPECIFIED Command is not supported by the ID tag 0x22 TAG_COMMAND_SYNTAX Parameter of the command wrong 0x23 TAG_OPTION_NOT_SUPPORTED ID t...

Страница 29: ...n case of malfunction u Do not open the housing as the unit does not contain any components which can be maintained by the user The unit must only be repaired by the manufacturer u Clean the device us...

Страница 30: ...or approvals and standards the following information is available Test standards and regulations documentation ifm com EU declaration of conformity and approvals documentation ifm com Notes relevant f...

Страница 31: ...non volatile memory IODD Digital description of the device The IODD is required for device parameter setting via IO Link IO Link IO Link is a standardised IO technology IEC 61131 9 for communicating...

Отзывы: