![IFM DTE801 Скачать руководство пользователя страница 20](http://html2.mh-extra.com/html/ifm/dte801/dte801_installation-instructions-manual_3950582020.webp)
20
8.4 LED indicators DTE802
The following LED indicators only apply to DTE802�
8.4.1 LED Mod (module status)
LED red
LED green
Status
Note
off
off
no voltage supply
check the voltage supply
off
flashing
ready for operation
Device is not configured�
There is no exchange of data:
►
Check the connection of
the Ethernet/IP scanner�
►
Check the parameter
setting of the configuration
assembly�
off
on
normal operation
Connection to the EtherNet/
IP scanner is established�
The device is configured� The
data transfer is running�
flashing
off
minor error
A connection to the EtherNet/
IP scanner was not
established:
►
Check the voltage supply�
►
Check the configuration of
the device�
on
off
major error
Software / hardware error of
the device:
►
Reboot the device�
> If the error remains, send
the device to the service�
flashing
flashing
self-test
starting phase of the device