7.2 Ethernet
►
Connect the device to a PC using a suitable M12 Ethernet connection cable�
The M12 Ethernet cable must be screened to ensure interference-free
operation�
1
2
3
4
Pin
Connection
1
TD+
2
RD+
3
TD-
4
RD-
Fig� 12: Pin connection fieldbus connection
7.2.1 Factory setting of the Ethernet parameters
The following values are preset at the factory:
Parameter
Factory setting
IP address
192�168�0�79
Gateway address
192�168�0�100
Subnet mask
255�255�255�0
Auto-negotiation
on
DHCP
off
The settings can be changed via the web server of the device or via the PC�