![IFM DP2200 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/ifm/dp2200/dp2200_operating-instructions-manual_620770014.webp)
DP2200
Analogue threshold display
14
8 Menu
8.1 General
Irrespective of the operating mode (standard IO mode or IO-Link device) there are two options to set
the parameters of the unit:
•
directly on the device via the menu (
Ò
Parameter setting)
•
or via an IO-Link tool
Access via an IO-Link tool has a higher priority than parameter setting via the menu.
Parameter cloning and parameter setting backup is possible with an IO-Link tool.
Some parameters can only be set via the IO-Link interface:
Parameters adjustable via IO-Link.
If the device was locked via IO-Link, it can also only be unlocked via the IO-Link interface:
Locking / unlocking (
22).
The scaling parameter [ScAL] only influences the display and not the transferred process data or the
actual switching threshold values.
Via IO-Link, the current value is always transmitted in μA → Representation of the measured current
value (
13). The switching thresholds can be set in steps of 0.01 mA.
If a scaling is set, the menu settings of the switching thresholds (SP, rP etc.) are also scaled.
Via IO-Link, however, the settings continue to be displayed and executed in steps of 0.01 mA
(resolution 10 bits).