DP2122
Speed monitor
24
OUT1
gn
rd
0 Hz
0 rpm
2000 Hz
120000 rpm
Fig. 13: Hysteresis function with [r1ou]
OUT1
rd
gn
0 Hz
0 rpm
2000 Hz
120000 rpm
Fig. 14: Hysteresis function with [G1ou]
For b/w printouts: gn = green, rd = red
•
[rEd] = continously red (independent of the measured value).
•
[GrEn] = continously green (independent of the measured value).
•
[r1ou] = red when OUT1 switches.
•
[G1ou] = green when OUT1 switches.
cFL
cFH
gn
gn
rd
0 Hz
0 rpm
2000 Hz
120000 rpm
Fig. 15: Window function with [r1ou]
cFL
cFH
rd
rd
gn
0 Hz
0 rpm
2000 Hz
120000 rpm
Fig. 16: Window function with [G1ou]
For b/w printouts: gn = green, rd = red
[r-cF] = red when the measured value is between the values [cFL] and [cFH].
[G-cF] = green when the measured value is between the values [cFL] and [cFH].
8.6.8 cFH/cFL ─ upper/lower value for colour change
If [coLr] is set to [r-cF] or [G-cF]
u
Select [cFH] and set the upper limit.
Setting range corresponds to the measured values. The lowest setting value is [cFL].
u
Select [cFL] and set the lower limit.
Setting range corresponds to the measured values. The highest setting value is [cFH].
cFL
cFH
gn
gn
rd
0 Hz
0 rpm
2000 Hz
120000 rpm
Fig. 17: Function [r-cF]
cFL
cFH
rd
rd
gn
0 Hz
0 rpm
2000 Hz
120000 rpm
Fig. 18: Function [G-cF]
For b/w printouts: gn = green, rd = red
8.6.9 diS.b ─ display power on
•
[OFF] = the measured value display is switched off in the operating mode.