UK
Installation instructions CANremote CR3114
25
[piece]
Environment
Ambient temperature [°C]
-30...75 °C
Protection
IP 65; for unit with screwed-on connectors
Tests / approvals
EMC
EN 61000-4-2 ESD:
6 kV contact discharge / 8 kV air discharge
EN 61000-4-4 Burst:
2 kV on supply lines / 1 kV on signal lines
EN 61000-4-5 Surge:
0.5 kV on supply lines
EN 61000-4-6 HF conducted:
10 V
EN 61000-4-3 HF radiated:
10 V/m (80...1000 MHz) / 3 V/m (1.4...2.7
GHz)
ISO 10605: 2008
8/15 kV / 8 kV
ISO 11452-4
60 mA (20...80 MHz) / 30 V/m (80...1000
MHz)
ISO 7637-2
1, 2a, 2b, 3a, 3b, 4, 5
CISPR 16-2
class B
CISPR25
radiated / met
Mechanical data
Housing materials
aluminium powder-coated
Electrical connection
Connection
M12 connector, 5-pole; FME connector, GSM antenna; SMA socket, GPS antenna
Wiring
1: GND
2: 6...32 V DC
3: Terminal 15 / Digital input
4: CAN_H
5: CAN_L
Remarks
Remarks
Put the device into operation with connected antennas only.
*) Program / configuration / data
Pack quantity
1
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — GB — CR3114-00 — 07.01.2015