Error tables
>
EMCY codes: I/Os, system
8412
EMCY code
object 0x1003
Object
0x1001
Manufactor specific information
Byte 0
[hex]
Byte 1
[hex]
Byte 2
[hex]
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Description
00
21
03
I0 LSB
I0 MSB
Inputs interruption
08
21
03
I0 LSB
I0 MSB
Inputs short circuit
10
21
03
I0 LSB
I0 MSB
Excess current 4…20 mA
00
23
03
Q0 LSB
Q0 MSB
Outputs interruption
08
23
03
Q0 LSB
Q0 MSB
Outputs short circuit
00
31
05
Power supply VBBS
00
33
05
Terminal voltage VU
08
33
05
Output voltage VBB1, VBB2
00
42
09
Excess temperature
In the CANopen stack none of these EMCY codes are fix implemented. Advice:
► Make these EMCY codes with CANOPEN_SENDEMCYMESSAGE.
>
Manufacturer-specific information (detail)
24551
The EMCY codes of the manufacturer-specific information for the inputs and outputs (if available) are
distributed as follows:
Byte
BYTE 3
Bit
7
6
5
4
3
2
1
0
I0 LSB
IN07
IN06
IN05
IN04
IN03
IN02
IN01
IN00
Q0 LSB
OUT07
OUT06
OUT05
OUT04
OUT03
OUT02
OUT01
OUT00
Byte
BYTE 4
Bit
7
6
5
4
3
2
1
0
I0 MSB
IN15
IN14
IN13
IN12
IN11
IN10
IN09
IN08
Q0 MSB
OUT15
OUT14
OUT13
OUT12
OUT11
OUT10
OUT09
OUT08