129
ifm
Programming Manual BasicController relay CR0431 v03.03.00
05 / 2018
ifm function elements
ifm function elements for the device CR0431
>
Parameters of the outputs
7919
Parameter
Data type
Description
ER
BYTE
Content of the error register 0x1001
ERROR_FIELD
ARRAY [0..MAXERR] OF
DWORD
Content of the error register 0x1003
Index 0 = number of the stored errors
Index 1...MAXERR = stored errors
The most recent error is in index 1
Preset: MAXERR = 5
RESULT
BYTE
feedback of the function block
(possible messages → following table)
Possible results for RESULT:
Value
dec | hex
Description
0
00
FB is inactive
1
01
function block execution completed without error
8
08
FB is active
– not yet processed
242
F2
Error: setting is not possible