6 Installation
6.1 Notes on the unit installation
When mounting several RFID units adhere to the minimum distances between the systems.
Flush mounting of a read/write head in metal reduces the read/write distance.
Device performance can be affected if positioned in the immediate vicinity of powerful HF
emission sources such as welding transformers or converters.
6.2 Avoiding interference
The device generates a modulated electrical field with a frequency of 13.56 MHz.
Avoid interference with data communication:
u
Do not operate any devices in the vicinity that use the same frequency band.
w
Such devices are for example frequency converters and switched-mode power supplies.
If there are other devices in the same frequency band in the vicinity:
u
The mounting distances between the devices should be as large as possible.
u
Use the devices in alternating operation.
u
Switch the HF field of the device on/off.
6.3 Mechanical design
On delivery the sensing face is facing the front.
Fig. 1: Factory setting