background image

ANT513

12

7 Electrical connection

The device must be connected by a qualified electrician.

Device of protection class III (PC III).

The electrical supply must only be made via PELV/SELV circuits.

u

Disconnect power before connecting the device.

7.1 Wiring

u

Connect the unit to a DTE10x evaluation unit via the M12 connector.

w

Voltage is supplied via the evaluation unit.

Pin assignment

Wiring

4

3

2

1

L+

1

3

4

L

DATA

Information on available sockets see: 

www.ifm.com

.

Cables with the following characteristics are suitable for the connection:

Length

Ohmic resistance (feed + return line)

Effective cable capacity

< 20 m

max. 3 Ω

max. 3 nF

Содержание ANT513

Страница 1: ...Operating instructions RF identification system ANT513 Read write head 11458694 00 05 2022 GB ...

Страница 2: ...gs 7 5 2 Device overview 7 6 Installation 8 6 1 Notes on the unit installation 8 6 2 Avoiding interference 8 6 3 Mechanical design 8 6 4 Alignment of the sensing face 9 6 5 Install device 9 6 6 Mounting distances 10 6 7 Positioning of the ID tag 10 7 Electrical connection 12 7 1 Wiring 12 8 Operating and display elements 13 9 Maintenance repair and disposal 14 10 Approvals standards 15 Glossary 16...

Страница 3: ... reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used ATTENTION Warning of damage to property 1 3 Legal and copyright information All rights reserved by ifm electronic gmbh No part of these instructions may be reproduced and used without the consent of ifm electronic gmbh All product names pictures companies or other bra...

Страница 4: ... purpose Ò Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator Installation electrical connection set up operation and maintenance of the product must be carried out by qualif...

Страница 5: ...e The read write head reads and writes ID tags without contact For use the read write head must be connected to the DTE10x evaluation unit The data is converted into digitally coded values and provided to the evaluation unit ...

Страница 6: ...ied Read write head 2x hexagonal nut The device is supplied without installation and connection accessories Available accessories www ifm com The optimum function is not ensured when using components from other manufacturers ...

Страница 7: ...ve coupling The integrated antenna coil in the read write head generates a magnetic field which partly penetrates the antenna coil of the ID tag A voltage is generated by induction that supplies the data carrier with energy The device supports ID tags according to ISO 15693 5 2 Device overview Article number ANT513 Function Read write head Type designation DTRHF MCRWIDUS03 Type rectangular ...

Страница 8: ...vice generates a modulated electrical field with a frequency of 13 56 MHz Avoid interference with data communication u Do not operate any devices in the vicinity that use the same frequency band w Such devices are for example frequency converters and switched mode power supplies If there are other devices in the same frequency band in the vicinity u The mounting distances between the devices shoul...

Страница 9: ...2 Adjustable antenna head 3 Fixing element 6 4 Alignment of the sensing face u Loosen the screw u Remove the antenna head from the fixing element and turn it u Attach the fixing element to the antenna head u Tighten the screw 6 5 Install device u Fix the device with 2 M5 screws and nuts ...

Страница 10: ...g distances Operating mode Distance side A Distance front B For reading and writing 300 mm 250 mm 6 7 Positioning of the ID tag For installation in or on metal use the ID tags provided for this purpose u Align the ID tag on the central axis of the antenna of the device ...

Страница 11: ...ANT513 11 w The distance D is indicated in the data sheet w All indications apply to static read write operations D Fig 5 Position the ID tag ...

Страница 12: ... before connecting the device 7 1 Wiring u Connect the unit to a DTE10x evaluation unit via the M12 connector w Voltage is supplied via the evaluation unit Pin assignment Wiring 4 3 2 1 L 1 3 4 L DATA Information on available sockets see www ifm com Cables with the following characteristics are suitable for the connection Length Ohmic resistance feed return line Effective cable capacity 20 m max 3...

Страница 13: ... voltage OK off operating voltage missing flashing slowly deactivated yellow on permanently ID tag detected on pulse ID tag read written successfully flashing quickly error when reading writing on ID tag off no ID tag in the field faulty ID tag in the field invalid ID tag in the field green and yellow flashing alternately error in communication or device fault ...

Страница 14: ...ase of malfunction u Do not open the housing as the unit does not contain any components which can be maintained by the user The unit must only be repaired by the manufacturer u Clean the device using a dry cloth u Dispose of the unit in accordance with the national environmental regulations ...

Страница 15: ...approvals and standards the following information is available Test standards and regulations documentation ifm com EU declaration of conformity and approvals documentation ifm com Notes relevant for approval package inserts of the device ...

Страница 16: ...ed to identify objects A read write device is used to read the ID tag via a high frequency radio signal An ID tag consists of an antenna an analogue circuit for receiving and transmitting transceiver a digital circuit and a non volatile memory ...

Отзывы: