background image

AL3150

Ethernet switch

4

2 Safety instructions

The unit described is a subcomponent for integration into a system.

– The system architect is responsible for the safety of the system.

– The system creator undertakes to perform a risk assessment and to create documentation in

accordance with legal and normative requirements to be provided to the operator and user of
the system. This documentation must contain all necessary information and safety instructions
for the operator, the user and, if applicable, for any service personnel authorised by the
architect of the system.

Read this document before setting up the product and keep it during the entire service life.

The product must be suitable for the corresponding applications and environmental conditions
without any restrictions.

Only use the product for its intended purpose (

Ò

 Intended use).

If the operating instructions or the technical data are not adhered to, personal injury and/or damage
to property may occur.

The manufacturer assumes no liability or warranty for any consequences caused by tampering with
the product or incorrect use by the operator.

Installation, electrical connection, set-up, operation and maintenance of the product must be
carried out by qualified personnel authorised by the machine operator.

Protect units and cables against damage.

Содержание AL3150

Страница 1: ...Operating instructions Ethernet switch AL3150 11392994 00 04 2021 GB ...

Страница 2: ...e output 6 5 Installation 7 5 1 Install device 7 6 Electrical connection 8 6 1 Overview 8 6 2 General wiring information 8 6 2 1 Cabling 8 6 3 Ethernet 8 6 4 Voltage output 9 6 5 Ground connection 9 6 6 Voltage supply 10 7 Operating and display elements 11 7 1 LEDs 11 7 1 1 Voltage supply 11 7 1 2 Ethernet 11 8 Set up 12 9 Maintenance repair and disposal 13 9 1 Cleaning the housing surface 13 ...

Страница 3: ...n the unit packaging or at www ifm com 1 1 Symbols used Requirement Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Change history Version Subject Date 00 New creation of the document 04 2021 GB ...

Страница 4: ...t of the system Read this document before setting up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose Ò Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property ...

Страница 5: ...nded use The device is used for networking of up to 6 Ethernet devices The device is designed for use in Ethernet networks The device is designed for use outside of a control cabinet The device is designed for the use in vehicles GB ...

Страница 6: ...2000 entries MAC Aging Time 200 400 s Quality of Service IEEE 802 1p IEEE 802 1Q Priority queues 4 4 2 Ethernet ports Supported transmission standards 10Base T IEEE 802 3i 100Base TX IEEE 802 3u Auto negotiation of the transmission rate Auto Negotiation Polarity detection and correction Auto Polarity Automatic detection of transmit and receive channels Auto MDI X 4 3 Voltage output The device has ...

Страница 7: ...ice u Disconnect the power of the machine before installation u Use a flat mounting surface for installation u Please observe the maximum tightening torque u Fasten the module onto the mounting surface using M5 screws and washers tightening torque 1 8 Nm GB ...

Страница 8: ...urfaces of the device with basic insulation according to EN61010 1 6 2 1 Cabling The M12 connection parts in the device comply with the ingress resistance requirements of the standard EN 61076 2 101 To adhere to the protection rating only cables certified to this standard must be used The system architect undertakes to ensure the ingress resistance of cables they have cut to length u Carry out the...

Страница 9: ...on rating IP 65 IP 66 IP 67 Wiring 2 4 1 3 5 1 24 V DC US 2 GND UA 3 GND US 4 24 V DC UA 5 FE u Observe the derating behaviour of the device 0 5 10 15 20 25 30 35 40 45 50 55 60 2 4 6 8 10 12 14 16 65 70 75 Temperature C Current A 1 2000 m 3000 m 4000 m Fig 1 Derating behaviour IUS daisy chain and IUA daisy chain at Port XD2 1 IUS daisy chain IUA daisy chain 6 5 Ground connection To ensure electri...

Страница 10: ...erse polarity protection US UA The port XD1 has an inrush current limitation ATTENTION Current surge with high voltage input due to disconnection of the device from battery supply while the engine is running w Damage to the device u When supplied by the on board system in vehicles do not disconnect the device from the battery when the engine is running u Disconnect power u Connect the device via p...

Страница 11: ... ACT port X1 7 1 1 Voltage supply LED Description Colour State Description US Voltage supply status Green off no supply voltage is applied or the applied supply voltage is too low on Supply voltage applied 7 1 2 Ethernet LED Description Colour State Description LNK ACT Status Connection Activity Green off no Ethernet connection on Ethernet connection established flashes Data transmission GB ...

Страница 12: ...t up u Install the device correctly u Establish a correct electrical connection with the device w Once connected to the supply voltage the device will start w The LEDs show the status of the device w The unit is ready for operation ...

Страница 13: ...way in accordance with the applicable national regulations when it is no longer used 9 1 Cleaning the housing surface Clean the surface of the device when necessary u Disconnect the device u Clean the device from dirt using a soft chemically untreated and dry cloth u In case of severe soiling use a damp cloth u Do not use any caustic cleaning agents for this GB ...