18
Solenoid monitoring contact ÜK
D2, D3
AS-Interface outputs
D0
interlocking solenoid, 1 = solenoid energised
D1
LED red, 1 = LED on
D2
LED green, 1 = LED on
AS-Interface LED Power
green, AS-Interface voltage applied
AS-Interface LED Fault
red, offline phase or address "0"
Reliability values to EN ISO 13849-1
B10
d
5 x 10
6
13 Terms and abbreviations
PL
Performance level
Capability of safety-related
parts to perform a safety function under
predictable conditions to fulfil the
expected risk reduction�
B10d
Number of cycles at which 10 % of the
components
have failed and caused danger�