14
10 Function check and troubleshooting
WARNING
Errors during installation and function check can lead to fatal injury�
►
Before the function check ensure that there are no persons in the hazardous
area�
►
Adhere to the applicable accident prevention regulations�
►
After installation and each error carry out a complete check of the safety
function�
10.1 Mechanical function check
The actuator must slide easily into the actuating head�
►
Close the safety guard several times to check the function�
10.2 Electrical function check
►
1� Switch the operating voltage on�
►
2� Close all safety guards�
►
In case of guard locking by means of solenoid force activate the guard locking�
The machine must not start automatically� It must not be possible to open the
safety guard�
►
3� Activate operation in the controller
It must not be possible to deactivate the guard locking as long as the operation is
active�
►
4� Switch off the operation in the controller and deactivate the guard locking�
The safety guard must remain locked until there is no longer a risk of injury� It must
not be possible to start the machine as long as the guard locking is deactivated�
►
Repeat steps 2 - 4 for every safety guard individually�
10.3 Troubleshooting
►
In case of damage or wear replace the complete switch and actuator assembly�
Replacement of individual parts or assemblies, especially of the actuating head, is
not permitted!
The production year is indicated in the bottom right corner of the type label�