SmartPLC DataLine with EtherCAT slave interface
55
Digital output
41465
Designation
Description
Example / Possible values
[Outputs]
Current values of the digital outputs
(binary and hexadecimal representation)
Data bit is switched off (0 / OFF)
Data bit is switched on (1 / ON)
[Jog mode]
The parameter controls the behaviour of
the outputs in the event of a changed
output value.
Jog mode disabled ("switch mode")
>
The changes do not affect the output until you
quit the editing mode.
Jog mode enabled ("momentary switch mode")
>
The changes immediately affect the output.
>
Analogue output
41521
Name
Description
Example / Possible values
[Outputs]
Current values of the analogue
output channels and information
about their status
[Analogue
status]
Current status of the analogue
outputs
Not O.K.
O.K.
[Channel x]
Current value of the analogue output
channel x
(x = 1...n; n = number of channels
per AS-i slave)
per digit:
0 ... 9
>
Parameter input
41787
Name
Description
Example / Possible values
[Parameter input]
Current value of the parameter input
(binary and hexadecimal
representation)
Data bit is switched off (0 / OFF)