5  Electrical connection

The unit must be connected by a qualified electrician�

 

The national and international regulations for the installation of electri-

cal equipment must be adhered to�

 

Ensure voltage supply to EN 50178, SELV, PELV� 

The following indications apply if there is a UL listing mark on the product:

 

For use in NFPA 79 applications only� Adapters providing field wiring 

means are available from the manufacturer� Refer to manufacturers 

information�

 

The device shall be supplied from an isolating transformer having a 

secondary Listed fuse rated   

a) max 5 amps for voltages 0���20 Vrms (0���28�3 Vp) or  

b) 100/Vp for voltages of 20���30 Vrms (28�3���42�4 Vp)� 

 

Disconnect power�

 

Connect the unit as follows:

DC PNP

pin 1 = L+

pin 3 = L-

pin 4 = OUT / IO-Link

DC NPN


pin 1 = L+

pin 3 = L-

pin 4 = OUT / IO-Link