22
10.3 Teach mode
10.3.1 Setting of the sampling rate
The sampling rate indicates the time after which a new result of
measurement is provided and the outputs are updated�
The switching frequency is typ� approx� 1/3 of the sampling rate�
►
Select [TEAC], then press [SET] and keep pressed until [WAIT] is
displayed�
> [rATE] and [rEPr] are displayed alternately�
►
When [rATE] is displayed: Press [SET] until the preset measured
sampling rate value flashes�
►
Enter a value incrementally by pressing [SET] once�
►
Confirm with [MODE/ENTER]�
> [WAIT] is displayed while the repeatability [rEPr] is calculated�
> The sampling rate [rATE] and the repeatability [rEPr] are displayed
alternately�
10.3.2 Setting of the repeatability
►
Select [TEAC], then press [SET] and keep pressed until [WAIT] is
displayed�
> [rATE] and [rEPr] are displayed alternately�
►
When [rEPr] is displayed: Press [SET] until the preset repeatability
value flashes�
►
Enter value incrementally by pressing [SET] once�
►
Confirm with [MODE/ENTER]�
> [WAIT] is displayed while the sampling rate [rATE] is calculated�
> The sampling rate [rATE] and the repeatability [rEPr] are displayed
alternately�