6
The fail-safe inductive sensor is a proximity device with defined behaviour under
fault conditions (PDDB) to IEC 60947-5-3�
The fail-safe sensor conforms to Performance Level e according to
EN ISO 13849-1 as well as to the requirements SIL 3 to IEC 61508 and meets
SILcl 3 to IEC 62061�
Depending on the type of installation the unit corresponds to the classification
I1C40SP2 to IEC 60947-5-2 for flush installation as well as I2C40SP2 to
IEC 60947-5-2 for non-flush installation (→ 6 Installation)�
The fail-safe inductive sensor has been certified by TÜVNord�
The unit is suited for applications up to 5 Hz�
5 Function
"0"
"1"
1: dual LED: signal (yellow); power (green)
2: close zone
3: enable zone
4: safe switch-off distance s
ar
5: target
5.1 Enable zone
The outputs (OSSD) are only enabled when a damping target is present in the en-
able zone� Outside this enable zone the outputs remain switched off�
The safe switch-off distance s
ar
is > 30 mm�
The enable zone is different if damping elements which deviate from the
standard target plate in terms of material, form and size are used�
Enable zone for selected materials*: