18
[mm]
[mm]
[s]
[ms]
[ms]
[ms]
[°C]
[K/min]
[%]
[kPa]
[m]
[h]
[1/h]
[kg]
Range
Enable zone
10...15
Safe switching off distance s(ar)
30
Reaction times
Power-on delay time
5
Response time to safety request
≤
50
Response time when approaching
the enable zone (enable time)
≤
200
Risk time (response time for safety
-related faults)
≤
100
Environment
Applications
Class C to EN 60654-1 weatherproof application
Ambient temperature
-25...70, for service life
≤
87600 h
10...40, for service life
≤
175200 h
Rate of temperature change
0.5
Max. relative air humidity
5...95, briefly
5...70, permanently
Air pressure
80...106
Height above sea level
≤
2000
Ionising radiation
not permissible
Salt spray
no
Protection
IP 65 / IP 67
Tests / approvals
EMC
IEC 60947-5-2
IEC 60947-5-3
EN 60947-5-2
EN 61000-4-2 ESD:
6 kV CD / 8 kV AD
EN 61000-4-3 HF radiated:
20 V/m
EN 61000-4-4 Burst:
2 kV
EN 61000-4-6 HF conducted:
10 V
EN 61000-4-8:
30 A/m
EN 55011:
class B
Shock resistance
IEC 60947-5-2
Vibration resistance
IEC 60947-5-2
Safety classification
Mission time TM
≤
175200, (20 years)
Safety-related reliability PFHd
2.5E-09
Mechanical data
Mounting
non-flush mountable
Housing materials
PPE; diecast zinc
Weight
0.346
Displays / operating elements
Display
LED yellow (signal), LED green (power)
Electrical connection
Connection
M12 connector; Gold-plated contacts
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — GB — GM701S-03 — 02.05.2016
Seite 2 von 3