![IFM Electronic Efector250 E3D304 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/ifm-electronic/efector250-e3d304/efector250-e3d304_installation-instructions-manual_3884424006.webp)
6
4� Tighten set screws
②
evenly�
> Tightening reduces the distance between the heat conductor and the device� The
heat conductor must lie flat on the device without air gap�
5� Tighten cylinder head bolts
①
with maximum 0,5 - 1,0 Nm�
6� Check that the heat conductor is aligned in a straight line and lies flat on the
device without gap�
> The surface temperature can only be reduced if the heat conductor lies flat on
the device without gap�
7� Mount the device on a 14 mm rod using a clamp�
4.1.2 Mount E3D302 for vertical operation of the device
Below you find a description how to mount the article E3D302 for vertical
operation of the device�
As the heat sink and the heat conductor are pre-mounted for horizontal operation
of the device, the heat sink must be rotated by 90 degrees�
Follow the instructions:
1� Loosen countersunk head screws
④
�
2� Rotate the heat sink
②
by 90 degrees�
> The cooling fins must be aligned vertically (see figure on the right)�
①
②
④
③