1  Preliminary note

This document is intended for specialists� These specialists are people who are 

qualified by their appropriate training and their experience to see risks and to 

avoid possible hazards that may be caused during operation or maintenance of 

the accessories� The document contains information about the correct handling of 

the accessories�
Read this document before use to familiarise yourself with operating conditions 

and installation� Keep this document during the entire duration of use of the 

accessories�

1.1  Symbols used

Instructions

>

Reaction, result

[…] Designation of keys, buttons or indications

Cross-reference

Important note 

Non-compliance may result in malfunction or interference

Information 

Supplementary note

2  Functions and features

The heat sink E3D302, E3D304 and the heat conductor E3D303 are accessories 

for O3D3xx type devices� The heat sinks and heat conductors are used to reduce 

the surface temperature of the devices depending on the operating mode�
The heat sinks can only be used in combination with a heat conductor� 
The heat conductor can be used without heat sink if it is mounted to a fixture with 

sufficient thermal conductivity�

Содержание Efector250 E3D304

Страница 1: ...Installation instructions Heat sink heat conductor E3D302 E3D303 E3D304 80231900 00 09 2015 UK...

Страница 2: ...3 E3D304 4 4 Installation 4 4 1 Mount E3D302 4 4 1 1 Mount E3D302 for horizontal operation of the device 5 4 1 2 Mount E3D302 for vertical operation of the device 6 4 2 Mount E3D303 8 4 3 Mount E3D30...

Страница 3: ...entire duration of use of the accessories 1 1 Symbols used Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunct...

Страница 4: ...bolts M5x70 2 cylinder head bolts M5x75 4 countersunk head screws M5x16 Installation instructions 3 3 E3D304 2 heat sinks and heat conductors pre mounted 2 cylinder head bolts M5x75 2 M5 nuts Clamp I...

Страница 5: ...ontal operation of the device Follow the instructions 1 Hold the heat conductor on one of the two device sides The hook of the heat conductor gets caught in the front of the device 2 Insert nuts in th...

Страница 6: ...ed if the heat conductor lies flat on the device without gap 7 Mount the device on a 14 mm rod using a clamp 4 1 2 Mount E3D302 for vertical operation of the device Below you find a description how to...

Страница 7: ...the bolt heads use the cylinder head bolts M5x70 7 Align the heat conductor in a straight line to the device 8 Tighten set screws evenly Tightening reduces the distance between the heat conductor and...

Страница 8: ...of a heat conductor with pre mounted nuts Mount the heat conductor E3D303 to a fixture with sufficient heat conductivity Below you find a description how to mount the heat conductor to a fixture and h...

Страница 9: ...75 with nuts by hand If the device has countersunk bore holes for the bolt heads use the cylinder head bolts M5x70 4 Align the device in a straight line to the heat conductor 5 Tighten set screws even...

Страница 10: ...with vertically aligned cooling fins This increases the degree of efficiency 4 3 1 Mount E3D304 for horizontal operation of the device Below you find a description how to mount the article E3D304 for...

Страница 11: ...device 4 Tighten set screws evenly Tightening reduces the distance between the heat conductor and the device The heat conductor must lie flat on the device without air gap 5 Tighten cylinder head bol...

Страница 12: ...s must be aligned vertically see figure on the right 3 Place both heat sinks on the bore holes of the heat conductors 4 Tighten countersunk head screws with maximum 2 0 3 0 Nm 5 Hold the heat conducto...

Страница 13: ...Nm 10 Check that the heat conductors are aligned in a straight line and lie flat on the device without gap The surface temperature can only be reduced if the heat conductors lie flat on the device wit...

Отзывы: