background image

UK

 

9

8.3  Lock / unlock the unit

The unit can be locked electronically to prevent unintentional settings�
Locking

 

► Press both setting buttons simultaneously for 10 s in the operating mode�

 

> The LED flashes green�

 

> After the time (> 10 s) has elapsed, the colour of the LED changes from green 

to yellow (flashing) and the unit is locked�

Unlocking

 

► Press both setting buttons simultaneously for 10 s in the operating mode�

 

> The LED continues to indicate the current operating status (no reaction of the 

LED)�

 

> After the time (> 10 s) has elapsed, the LED flashes green and the unit is 

unlocked�

On delivery: unlocked�

9  Operation

When the supply voltage has been applied, the unit is in the operating mode� It 

carries out its measurement and evaluation functions and switches the output�
Operation indication by LED:

LED

Status / function

Green

unit ready for operation, sensor zone covered (output open (OFF))

Yellow

unit ready for operation, sensor zone not covered (output closed (ON))

10  Maintenance, repair, disposal 

Recommended maintenance:

 

► Check the probe for build-up from time to time, clean it in case of strong soiling�

After removal of the unit or a change of media with dielectric constants that 

differ greatly (e�g� oil / water) another adjustment should be carried out�

It is not possible to repair the unit�

After use dispose of the unit in an environmentally friendly way in accordance with 

the applicable national regulations�

Содержание efector160 LI214 Series

Страница 1: ...Operating instructions Binary level sensor LI214x 704776 00 10 2010 UK...

Страница 2: ...rinciple 4 4 2 Features of the unit 5 5 Installation 5 5 1 Installation location environment 5 5 2 Mounting 6 5 3 Set the installation depth 6 6 Electrical connection 7 7 Operating and display element...

Страница 3: ...t the product is suitable for your application without any restrictions If the operating instructions or the technical data are not adhered to personal injury and or damage to property can occur Insta...

Страница 4: ...te mounting accessories chapter 5 2 Installation procedure 4 Function 4 1 Measuring principle The unit operates to the capacitive measuring principle By direct contact with the medium the unit detects...

Страница 5: ...le detection of media with a very low dielectric constant e g oil The installation depth determines the level 5 3 The unit is virtually immune to almost any kind of build up on the probe The position...

Страница 6: ...ssure rating of 0 5 bar E43006 flange plate 65 80 with clamp adapter aluminium pressure rating of 0 5 bar E43007 flange plate 54 52x52 with clamp adapter aluminium pressure rating of 0 5 bar E43016 mo...

Страница 7: ...age supply to EN 50178 SELV PELV Disconnect power Connect the unit as follows 3 1 4 2 L L 1 4 3 Pin1 L Pin4 switching output NC Pin3 L Core colours of ifm sockets 1 BN brown 3 BU blue 4 BK black 7 Ope...

Страница 8: ...rocess the yellow LED is lit con tinuously unit is in the operating mode sensor zone not covered 8 2 Set to the full vessel The empty adjustment is sufficient for media with a low dielectric constant...

Страница 9: ...ation When the supply voltage has been applied the unit is in the operating mode It carries out its measurement and evaluation functions and switches the output Operation indication by LED LED Status...

Страница 10: ...nstant medium 1 8 Max tank pressure bar 0 51 Housing materials PP GF orange TPE U Materials wetted parts PP Protection IP 65 IP 67 Protection class II Ambient temperature C 0 60 Medium temperature oil...

Отзывы: