9. Technical data
Order no.: G15003
Electrical design:
PNP and NPN solid-state outputs
Output function:
switched if all connected units are enabled
with switch-off pulses of approx. 400 µs with a
period of approx. 300 ms
Operating voltage:
18 ... 30 V DC
Auxiliary voltage:
18 ... 30 V DC
This supply voltage must be of type PELV.
Current consumption:
200 mA + n x 15 mA
(n = number of the connected sensors)
Current rating:
< 200 mA
Voltage drop:
< 2.5 V (at max. load)
Short-circuit protection:
yes
Output status indication:
LED
Power-on delay time t
for enabling:
typ. 5 s (power on)
Response time:
1 s for safety enabling
210 ms for safety requirement
page 24
105
35,5
50
11
4
LEDs
Содержание efector100 G15003
Страница 38: ...page 38 ...