9.5.8 Offset value
The offset value is calculated in the preset function and exchanges the position
value for the calculated value�
9.5.9 Scaling parameters
The scaling parameters are used to change the resolution� This parameter only
refers to the output values if the scaling function is enabled�
Parameter
Meaning
Data type
Measuring units
per revolution
Singleturn resolution in steps
Unsigned 32
Total measuring range
in measuring units
Total measuring range
Unsigned 32
If the resolution per revolution is reduced, a skip in the position value may occur when crossing the
physical zero point�
Reason: The position values exceed the real total resolution�
Use the formula below to avoid this problem:
Total resolution = desired measuring steps / revolution x revolutions
9.5.10 Maximum master sign-of-life failures
With this parameter the number of allowed failures of the master's sign of life is
defined�
Parameter
Meaning
Value
Maximum master sign-of-
life failures
Number of permissible failures
of the sign-of-life counter
0 … 255
Standard =1
9.5.11 Velocity measuring units
This parameter defines the coding of velocity measuring unit used to configure the
values NIST_A and NIST_B� Only telegrams 82-84 use the velocity outputs�
Velocity unit
Value
Steps / s
0
Steps / 100 ms
1
Steps / 10 ms
2
RPM
3
N2/N4
4