Encoder with ProfiNet interface
12
All values are presented in binary format� If an error occurs, G1_XIST2 displays
the error telegram instead of the right-aligned value�
The shifting factors in P979 "sensor format" display the current format� P979,
subindex 4 (shift factor for G1_XIST2) = 0� The settings in the encoder parameter
data affect the position value in both G1_XIST1 and G1_XIST2�
Absolute value in G1_XIST2
31���25
24���13
12���0
M
S
Distinguishable
revolutions
(multiturn value)
Pulses
(singleturn steps
per revolution)
Setting: encoder profile 4.0*
●
By default, G1_XIST1 is left-aligned�
●
P979, subindex 3 (shift factor for G1_XIST1) = 32 – total resolution (next binary
value)
●
G1_XIST1 transmits positions values independent of bit 10 in stw2 and bit 13 in
g1_stw1�
Absolute value in G1_XIST1 for encoder profile 4�0
31���20
19���7
6���0
M
S
Distinguishable
revolutions
(multiturn value)
Pulses
(singleturn steps
per revolution)
Setting: encoder profile 4.1*
●
By default, G1_XIST1 is right-aligned�
●
A 32-bit counter starts with the absolute position value� After increasing to the
maximum counter value, start again with 0 or decreasing from the max� counter
value to 0�
●
P979, subindex 3 (shift factor for G1_XIST1) = 0
●
G1_XIST1 transmits positions values independent of bit 10 in stw2 and bit 13 in
g1_stw1�
Absolute value in G1_XIST1 for encoder profile 4�1
31���13
19���0
M
S
Distinguishable
revolutions
(multiturn value)
Pulses
(singleturn steps
per revolution)