48
ifm
Device Manual IO-Link Master with PROFINET interface CabinetLine 8 Ports IP 20 (AL1900)
05 / 2018
Configuration
IoT Core
>
8.3.8
Control IO-Link master
17963
The device can be controlled via the following services:
Service
Description
Access
firmware/version
Firmware version of the IO-Link master
r
firmware/reboot
Reboot IO-Link master
rw
firmware/signal
Identify IO-Link master
rw
firmware/factoryreset
Reset IO-Link master to factory settings
rw
r ... read only
rw ... read and write
>
8.3.9
Read device information
17133
Device information is saved in the
deviceinfo
substructure. The user can access the following data
points:
Name
Description
Access
deviceinfo/productcode
Article Number
r
deviceinfo/vendor
Vendor
r
deviceinfo/devicefamily
Device family
r
deviceinfo/hwrevision
Hardware revision
r
deviceinfo/serialnumber
Serial number
r
deviceinfo/swrevision
Firmware version
r
deviceinfo/bootloaderrevision
Bootloader revision
r
deviceinfo/extensionrevisions
r
deviceinfo/fieldbustype
Fieldbus
r
r = read only
Additional information about the AL1900 can be read with the
getidentity
service (
→
Service:
getidentity
(