107
ifm
Operating Instructions IO-Link Master with EtherNet/IP interface StandardLine 8 Ports IP 65 / IP 67 (AL1122)
2017-05-31
Appendix
Attr. ID Access Name
Data type
Description
Preset
1
Internal interface
2
Twisted pair
3
Optical fibre
4...255
reserved
8
Get
Interface state
USINT
Current status of the interface
0
0
unknown
1
active; ready for transmission and
reception
2
not active
3
Test mode
4...255
reserved
9
Get
Admin State
USINT
Control of the access to the interface
1
0
reserved
1
Activate interface
2
Deactivate interface
3...255
reserved
10
Get
Interface label
SHORT_
STRING
Designation of the interface
"X21" (instance 1)
"X22" (instance 2)
11
Get
Interface capability
STRUCT of
Capabilities of the interface
DWORD Transmission rate
10
10 Mbps
100
100 Mbps
DWORD Duplex mode
HD
Half duplex
FD
Full duplex
300
Get, Set MDIX
???
MDIX configuration
3
0
1
MDI
2
MDIX
3
autoMDI
4...255
reserved
>
Supported services
23665
Service code
Name
Class
Attribute
Description
dec
hex
01
01
Get_Attribute_All
no
yes
Read all attribute values
14
0E
Get_Attribute_Single
yes
yes
Read single attribute value
16
10
Set_Attribute_Single
no
yes
Change single attribute value