background image

Operating instructions 

AS-i controller

e

AC1391 

AC1392 

7390920/00

 

12/201

1

UK

Содержание AC1391

Страница 1: ...Operating instructions AS i controllere AC1391 AC1392 7390920 00 12 2011 UK ...

Страница 2: ...gramming Interface 4 4 Installation 4 5 Electrical connection 5 6 Operating and display elements 6 6 1 LED indicators and pin connection 6 6 1 1 LEDs 7 6 1 2 Diagnostic LEDs 7 6 1 3 Status LEDs on the network connection 7 6 2 Contrast setting 8 7 Operation 8 8 Menu overview 9 8 1 Password 9 8 2 Menu navigation 10 9 Technical data 13 9 1 Data sheets 13 9 2 Programming manual 13 10 Maintenance repai...

Страница 3: ...or indications Cross reference Important note Non compliance can result in malfunction or interference Information Supplementary note 2 Safety instructions 2 1 General Observe these operating instructions Adhere to the warning notes on the product Non observance of the instructions operation which is not in accordance with use as prescribed below wrong installation or incorrect handling can affect...

Страница 4: ...nsor actuator level It processes the peripheral data in the integrated processor signal preprocessing It works as stand alone controller with exchange of data to the PC visualisation It communicates with the superior control level EtherCAT 3 1 Programming interface RS232C Baud rate 4800 to 115 200 baud Max distance between controllere and PC 20 m Potential separation from the controllere power sup...

Страница 5: ...he installation from power Connect the unit as indicated on the terminals Never connect the minus potentials to each other or the minus potentials to the FE connection Ensure an electrically save ground connection between AS i controllere terminal FE and ground of the unit Supply the controllere with a 24 V DC voltage 20 30V PELV e g from the 24 V power supply DN3011 from ifm electronic The connec...

Страница 6: ... J C O N F P F 2 4 V P W R P L C R U N 1 Status LEDs on the network connection 2 Display 3 Setting buttons 4 LEDs ASI2 only with AC1392 5 EtherCAT interfaces 6 Wiring 7 RS232C interface 6 1 1 LEDs LED 24 V PWR green off no 24 V voltage supply available lights 24 V voltage supply available LED PLC RUN yellow off PLC in the operating mode stop lights PLC in the operating mode run ...

Страница 7: ...uration do not match LED CONF PF flashes Peripheral fault on at least one connected slave 6 1 3 Status LEDs on the network connection LED RUN green off Module in the Init state flashes Module in the pre operational state flashes 1x pause Module in the safe operational state lights Module in the operational state LED ERR red off EtherCAT communication active flashes General configuration error flas...

Страница 8: ...ellow AS i cable with energy and implements a data decoupling to the voltage regulator of the power supply Standard switched mode power supplies would consider the AS i data signals as interference signals and suppress them Disconnect the power supply before connecting the controllere The AS i system is operated ungrounded AS i and AS i are to be symmetrical to the ground potential of the installa...

Страница 9: ...erman and English menu MENU USER 8 1 Password In the menu System Setup menu item Password the handling can be restricted or enabled When delivered the device is in the user mode By entering an invalid password e g 1000 all menu items which can change settings are blocked By entering the password CE01 the user mode is enabled again The password is stored non volatilely by the System Setup Store Sys...

Страница 10: ...the PLC in the controllere if used PLC info Display of the user program name author date Slave lists Checking of the addresses of the connected AS i slaves Indication of the list of detected slaves LDS Indication of the list of projected slaves LPS Indication of the list of activated slaves LAS Indication of the list of periphery faults in AS i slaves LPF Slave addresses Programming of the address...

Страница 11: ...ation of the maximum system cycle time Reading the diagnostic information of Safety at Work monitors Master setup Information about the AS i master system Teach in of the current AS i configuration project all Changeover to the projection mode configuration of the AS i system Changeover to the protected mode normal operation master monitors configuration Enable the automatic AS i slave addressing ...

Страница 12: ...rrent and projected parameters of the connected AS i slaves Current and projected I O and ID codes of the connected AS i slaves Message errors in the communication to the connected AS i slaves System setup Device settings of the controllere Store the current system settings Setting of the baud rate of the serial programming interface Setting of the parameters of the Ethernet programming interface ...

Страница 13: ... master 2A Module 14 analogue input master 1 Module 5 digital inputs master 1B Module 15 analogue output master 1 Module 6 digital outputs master 1B Module 16 analogue input master 2 Module 7 digital inputs master 2B Module 17 analogue output master 2 Module 8 digital outputs master 2B Module 18 diagnosis Module 9 analogue multiplexed input Module 19 host command channel Module 10 analogue multipl...

Страница 14: ... the device in accordance with the national environmental regulations 11 Approvals standards The EC declaration of conformity and approvals can be found at www ifm com data sheet search AC1391 AC1392 Approvals 12 Scale drawing 4 107 97 86 124 131 62 ...

Отзывы: