29
GB
out his job), for the customer (if envisioned) and
for routine maintenance interventions.
- A space of at least 50 cm must be left in
correspondence with the ventilation grids for the
$ %$Q<
- If the product unit is positioned at the centre of
# >
overhead arrival tract for the power supply cable.
Position the counter in the space established,
remembering to remove the two planks on the base
# $
The counter must be positioned in a way that it is
perfectly level (Fig. 7).
$ # W
- there is sufficient air circulation around the
counter, but not currents;
- The counter is not in the vicinity of hot air sources;
$%$[<\
- the condenser cooling air passage grids are not
obstructed;
- any air conditioning or room heating is not aimed
towards the display unit.
NOTE!
T h e a b o v e - m e n t i o n e d i n d i c a t i o n s
must be respected in order to prevent
malfunctioning, which will not be covered
by the warranty.
2.4 ENVIRONMENTAL SPECIFICATIONS
ATTENTION!
The display unit can operate in a
maximum environment temperature of
32°C and 60% relative humidity, if the
appliance undergoes regular scheduled
maintenance.
2.5 MOUNTING THE FEET
ATTENTION CRUSHING HAZARD
Operation performed by 2/3 persons.
%$]<
to unscrew the feet and remove the wooden cross
beams.
ATTENTION!
This operation must be performed with
great care, inserting the safety elements
during the operation.
Re-mount the feet using the lock nut (Fig. 9) and
screw them to half way of their stroke (they will be
adjusted and tightened in the successive phases).
_
Adjust the feet to take the body to the correct height
and make it level (Fig. 7, Pos. A)
Once level, tighten the lock nuts on the feet.
NOTE:
the feet can be extracted to a maximum
of 20 mm.
A
Fig. 7
Fig. 8
Fig. 9