www.ies-synergy.com
Installation Manual
DIM016055-EN
35
Booting errors
Message
Description
Error connecting server.
Message displayed during the startup of the
charging station if the backend server reject the
connection.
Error connecting to rfid reader.
Message displayed during the startup of the
charging station if the RFID does not work. Please
see the maintenance manual.
Error connecting to comm control unit.
Message displayed during the startup of the
charging station if the CCU does not work. Please
see the maintenance manual.
Power limitation
If necessary, you can limit the power delivered by the charging station on the backend server.
For the charging station, use the OCPP frame “Change Configuration” to adjust the following configuration
parameters:
Configuration parameters
details
Expected
v a l u e
type
D e f a u l t
value
Description
PowerLimit
Watts
24000
Maximum power to be delivered by the charger. Al-
low to limit the output power below 24kW.
VoltageSupplyLimit
Volt
230
The nominal value of the single-phase voltage pro-
vided in the country. Usually 230V in Europe.
CurrentInputLimit
Amp
40
The maximum current allowed by the power supply
installation (value of the circuit-breaker installed
outside the charger).
Refer to your backend server instructions to know how to change these configuration parameters.
Содержание Wallbox G3
Страница 1: ...Installation Manual for Wallbox G3 www ies synergy com DIM016055 EN_V002 ...
Страница 37: ...www ies synergy com Installation Manual DIM016055 EN 37 Notes ...
Страница 38: ...www ies synergy com Installation Manual DIM016055 EN 38 Notes ...
Страница 39: ...www ies synergy com Installation Manual DIM016055 EN 39 Notes ...