5. Specifications
AC Main supply specifications
Mains supply 3-phase L1/L2/L3 + N + PE
Mains 3-phase voltage range
V
AC
230/400 V
AC
± 10%
Earthed electrical system
TT; TN
Frequency range
f
50 Hz
+4%/-6%
Nominal input current
I
IN
279A
Nom
Maximum input current
InA
313 A
Max
Presumed short circuit current
Icc
25kA
Max
Power Factor
PF
0,99
Nom
Efficiency
ɳ
0,95
Max
Harmonic current @ nominal network voltage
THDi
< 7 %
Max
Internal protection of mains inputs
Inrush current limitation per phase
I
INRUSH LIMIT
< 3 x I
AC
Max
Max earth leakage current
I
LEAKAGE
< 3,5 mA
Max
Emergency button connection
Yes in version for fleets, not in version for public access
Overvoltage category
III
Rated Impulse Voltage
6kV
Rated Insulation Voltage (IEC 61439)
690 V
AC
DC output specifications
DC Output Electrical System: IT
Output voltage range
V
DC
_max
1000 V
DC
Max
V
DC
_min
200 V
DC
Min
Output current range
I
DC
_max
390A
(1)(2)
Max
I
DC
_min
1,5A
Min
Max Output Power
P
OUT
180kW
Max
Minimum Short-Circuit Ratio (IEC 61000-3-12)
Rsce
33
VA/VA
Connection
4 Wires + PE
Output connector (charging station side)
Permanent mounting
Car Plug connectors
CCS type2 - IEC 62196-3
Output cable length
Meters
3,15m / 5,5m / 9,5m
(5)
Cable management system
Yes optional (from 4m to 7,5m) / Mandatory from 7,5m
DC output protection
Hardware and software short circuit protection
Yes
Hardware over voltage protection
Yes
Software over voltage protection
Yes
Over temperature protection
Yes
Reverse polarity protection
Yes
DC output contactor
Yes (2 poles)
Rated current fuse (output)
I
FUSE
600
A
Galvanic isolation
V
input / output
V
DC
Max time for DC line discharge < 60V
T
<60V
1
s