User Manual
DUM4021418-EN
10
www.ies-synergy.com
By
EV Detection Loop characteristics
The equipment is designed to be connected to two independent vehicle parking loops and provide detection.
Frequency is determined by loop geometry.
Frequency Bands
18-110 KHz
Loop customization (1m x 1m)
20.4dBuA/m
Radar characteristics
Operating Frequency
61.0 GHz to 61.5GHz
General & dimensions
External dimensions w/o cable support (HxWxD)
mm
2000 x 899 x 865
± 5%
External dimensions with cable support (HxWxD)
mm
2000 x 899 x 1115
± 5%
Weight (with DC cable and cable management)
Kg
600 (S180)
570 (S150)
540 (S120)
Max
Type of installation
Indoor or outdoor
Fixation points
4
Mechanical resistance to impact
IK
IK10
(IK09 on screen)
Protection Type (EN60529)
IP
IP55
Cooling system
Air
Climatic & Environment constraints
Operating temperature (with derating)
-25°C to +50°C
(3)
(-20°C à +50°C If payment terminal)
Storage temperature
-25°C to +70°C
Relative humidity
RH
10% to 95%
Installation altitude
Alt
2 000 m
Max
Norms & standards
Low voltage EC directive (LVD)
2014 / 35 / UE
EC Electromagnetic directive
2014 / 30 / UE
Radio Equipment Directive
2014 / 53 / UE
Electric vehicle conductive charging system – Part 1: General requirements
EN61851-1:2019
ELECTRIC VEHICLE CONDUCTIVE CHARGING SYSTEM – Part 23: DC electric vehicle supply equipment EN61851-23
Digital communication between a d.c. EV charging station and an electric vehicle for control of
D.C. charging
IEC61851-24
Part 21-2 EMC requirements for OFF board electric Vehicle charging system
IEC61851-21-2
Low-voltage switchgear and controlgear assemblies – Part 1: General rules
IEC61439-1:2020
Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications
such as marinas, camping sites, market squares, electric vehicle charging stations
IEC 61439-7:2018
+ COR1:2019
(1)
Max output current will be adapted versus maximum carrying current of the vehicle plug.
(2)
Output current can be even reduced with the power derating versus temperature.
(3)
With derating from 35°C.
(4)
Design in compliance with CE directives.
(5)
May change depending on version.