EN
8 - TROUBLES - CAUSES - CURES
SIR 52 MS52 P/F
8 - Pag. 2 / 10
8.1 GENERAL
PROBLEMS
INCONVENIENTS CAUSE
REMEDY
Open cases.
Close the cases
The feeding drum is out of
position.
Bring the feeding drum to position
and reassemble coupling screws
between the bell of the lathe and
the bell of the bar feeder.
Air missing.
Check the air system.
Emergency devices activated. Disable the emergency devices.
BAR FEEDER DOES NOT START
Motors thermal switches
blown.
Reset the overload relay by means
of the relevant push-buttons.
Levers are in a loading phase.
Clamp arm on the guides.
Clamps are closed.
THE BAR FEEDER DOES NOT
WORK IN THE AUTOMATIC
MODE
Guides are open.
Read for any possible defects on the
DISPLAY and provide the required
conditions for the bar feeder to be
started automatically.
Содержание SIR52 MS52 F
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 20: ...EN 2 TECHNICAL INFORMATION SIR 52 MS52 P F 2 Pag 10 14 2 6 TECHNICAL INFORMATION ...
Страница 24: ...EN 2 TECHNICAL INFORMATION SIR 52 MS52 P F 2 Pag 14 14 ...
Страница 50: ...EN 4 HANDLING AND INSTALLATION SIR 52 MS52 P F 4 Pag 22 22 ...
Страница 72: ...EN 5 ADJUSTMENTS AND SETTING UP SIR 52 MS52 P F 5 Pag 22 22 ...
Страница 102: ...EN 6 USE AND OPERATION SIR 52 MS52 P F 6 Pag 30 30 ...
Страница 148: ...EN 9 PART REPLACEMENT SIR 52 MS52 P F 9 Pag 16 16 ...
Страница 174: ...EN 11 GUIDE CHANNELS BAR PUSHER REVOLVING TIPS SIR 52 MS52 P F 11 Pag 6 6 ...
Страница 185: ...12 GRIPPERS SIR 52 MS52 P F EN 12 Pag 11 34 ...
Страница 203: ...12 GRIPPERS SIR 52 MS52 P F EN 12 Pag 29 34 ...
Страница 209: ...13 LIST OF AFTER SALES CENTERS SIR 52 MS52 P F EN 13 Pag 1 4 INDEX 13 1 LIST OF AFTER SALES CENTERS 2 ...
Страница 212: ...EN 13 LIST OF AFTER SALES CENTERS SIR 52 MS52 P F 13 Pag 4 4 ...